Warning: mkdir(): No space left on device in /www/wwwroot/zhenghe1718.com/func.php on line 127

Warning: file_put_contents(./cachefile_yuan/pkscc.com/cache/32/77d29/a1261.html): failed to open stream: No such file or directory in /www/wwwroot/zhenghe1718.com/func.php on line 115
Anti-CCP EDIA™ (FCCP100) |产品详情|进口橙子视频旧款采购网




  • 橙子视频app安卓下载,91橙子视频,橙子视频旧款,橙子视频在线官网

    订购信息
    上海橙子视频app安卓下载生物科技公司
    Tel:400-968-7988    021-33779008
    Anti-CCP EDIA™ (FCCP100)
    品牌:Svar Life Science
    货号:
    规格:
    货期:

    Anti-CCP EDIA™ (FCCP100)

    商品详情 参考文献 相关资料

    Anti-CCP EDIA™

    Add to my product list

    Antibodies against cyclic citrullinated peptide (anti-CCP) are highly specific for rheumatoid arthritis (RA), one of the most common systemic autoimmune diseases affecting up to 1-2% of the world population. Euro Diagnostica in collaboration with world class scientists invented anti-CCP testing and the anti-CCP2 test is recognized as the gold standard of testing for anti-CCP. Today, Euro Diagnostica manufactures and supplies the majority of anti-CCP2 in the world.

    The presence of anti-citrullinated protein antibodies is now one of the ACR-criteria for classification of RA. The EDIA™ anti-CCP assay is based on highly purified synthetic peptides containing citrulline residues and is an additional tool in the diagnosis of RA. This anti-CCP kit contains improved synthetic peptides selected on the basis of superior performance in the detection of RA autoantibodies.

    Product code
    FCCP100
    Format
    ELISA
    Tests
    96 wells
    Calculation
    Semi-quantitative
    Antigen
    CCP2
    Units
    U/mL
    Calibrators
    6
    Range
    0-300 U/mL
    Incubation time
    60+30+30 min
    Detection system
    ALP/PMP (550 nm)
    Availability
    CE marked. For sale in US
    • Intended use
    • Product Details

    Intended use

    The EDIA™ anti-CCP test kit is an enzyme-linked immunosorbent assay (ELISA) for detection and semi-quantitation of IgG antibodies to Cyclic Citrullinated Peptides (CCP) in human serum or plasma. The assay is used to detect antibodies in a single specimen. The results of the assay are to be used as an aid to the diagnosis of Rheumatoid Arthritis (RA), in conjunction with other laboratory and clinical findings. The analysis should be performed by trained laboratory professionals. For in vitro diagnostic use.

     

    Background

    Rheumatoid Arthritis (RA) is one of the most common systemic autoimmune diseases.

    The aetiology of the disease, which affects up to 1-2% of the world population, is unknown. The diagnosis of RA depends primarily on clinical manifestation of the disease. The only serological test routinely used is the determination of the presence of rheumatoid factors (RF) in the serum. RF are antibodies directed to the constant region of immunoglobulins of the IgG class. However, these antibodies are also present in relatively high percentages in other autoimmune diseases, infections and in up to 15% of healthy individuals.

    Antibodies of a more specific nature have also been found in sera of RA patients. Anti-perinuclear factor (APF) antibodies are reported to be present in around 50% of RA patients with a specificity of over 70%. A number of cyclic synthetic peptides not related to filaggrin or other known proteins have been described which are specifically recognized by autoantibodies in sera from RA patients. These peptides were subsequently used in an ELISA for the detection of RA-specific autoantibodies. Clinical evalsuation studies showed that the ELISA was positive in a significant number of well-defined RA patient sera with a high specificity against disease controls. A diagnostic and prognostic value for the measurement of the anti Cyclic Citrullinated Peptides (anti-CCP) antibodies was found in relation to joint involvement and radiological damage in early RA. The EDIA™ anti-CCP assay offered by Euro-Diagnostica is based on highly purified synthetic peptides containing citrulline residues and is an additional tool in the diagnosis of RA. This anti-CCP kit contains improved synthetic peptides selected on the basis of performance in the detection of RA autoantibodies. The sensitivity of the test has been shown to be 76%. The specificity was 98% with diseased non-RA patients and 99% with apparently healthy individuals.

    Technical information

    The EDIA™ anti-CCP antibody kit is based on an ELISA method. The test utilizes microtitre wells coated with citrullinated synthetic peptides (antigen). Diluted patient serum or plasma is applied to the wells and incubated. If specific antibodies are present, they will bind to the antigen in the wells. Unbound material is washed away and any bound antibody is detected by adding alkaline phosphatase labelled antibodies to human IgG, followed by a second washing step and incubation with a chromogenic substrate.

    The presence of reacting antibodies will result in the development of colour, which is proportional to the quantity of bound antibody, and this is determined photometrically.

    • 关于橙子视频app安卓下载
    • 购物流程
    • 支付方式
    • 配送方式
    Copyright@ 2003-2025  进口橙子视频旧款采购网版权所有     

    BIOLEAF热搜   BIOLEAF91橙子视频   BIOLEAF ELISA   BIOLEAF橙子视频旧款   BIOLEAF品牌   BIOLEAF抗体   BIOLEAF耗材   BIOLEAF小仪器

    sitemap   细胞库查询   危险品图标

    本公司网站所展示销售的产品仅供科研!

             沪ICP备08023583号-6     
    产品咨询
    QQ扫码沟通
    在线客服
    服务电话
    400-968-7988
    扫码关注
    微信公众号二维码

    沪公网安备 31011202007338号

    网站地图